Gorman-rupp-pumps PA6C60-4045T-ESP 1479001 thru 1302081 Manuel d'utilisateur

Naviguer en ligne ou télécharger Manuel d'utilisateur pour Pompes Gorman-rupp-pumps PA6C60-4045T-ESP 1479001 thru 1302081. Gorman-Rupp Pumps PA6C60-4045T-ESP 1479001 thru 1302081 User Manual Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 52
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 0
OM−06341−03
February 04, 2011
ACDEU
THE GORMAN-RUPP COMPANY MANSFIELD, OHIO
www.grpumps.com
GORMAN-RUPP OF CANADA LIMITED ST. THOMAS, ONTARIO, CANADA Printed in U.S.A.
2011 The Gorman-Rupp Company
INSTALLATION, OPERATION,
AND MAINTENANCE MANUAL
WITH PARTS LIST
PA SERIES PUMP
MODEL
PA6C60−4045T−ESP
Vue de la page 0
1 2 3 4 5 6 ... 51 52

Résumé du contenu

Page 1 - PA6C60−4045T−ESP

OM−06341−03February 04, 2011ACDEUTHE GORMAN-RUPP COMPANY  MANSFIELD, OHIOwww.grpumps.comGORMAN-RUPP OF CANADA LIMITED  ST. THOMAS, ONTARIO, CANADA

Page 2

PA SERIES OM−06341PAGE B − 3INSTALLATIONthe brake and blocking the wheels before attempt-ing to operate the pump.If the pump has been mounted on a mov

Page 3

OM−06341 PA SERIESPAGE B − 4 INSTALLATIONSealingSince even a slight leak will affect priming, head,and capacity, especially when operating with ahigh

Page 4 - (continued)

PA SERIES OM−06341PAGE B − 5INSTALLATIONFigure 2. Recommended Minimum Suction Line Submergence vs. VelocityDISCHARGE LINESSiphoningDo not terminate t

Page 5 - INTRODUCTION

OM−06341 PA SERIESPAGE B − 6 INSTALLATIONFloat Switch InstallationThe Float Switch autostart system employs either asingle or double float switch, whe

Page 6 - SAFETY - SECTION A

OM−06341PA SERIESOPERATION PAGE C − 1OPERATION − SECTION CReview all SAFETY information in Section A.Follow the instructions on all tags, labels andde

Page 7 - PAGE A − 2 SAFETY

OM−06341 PA SERIESOPERATIONPAGE C − 2AL’. After the engine starts and the unit is fullyprimed, adjust the engine RPM until the desiredflow rate is ach

Page 8 - INSTALLATION − SECTION B

OM−06341PA SERIESOPERATION PAGE C − 3connections or fittings. Keep all line connectionsand fittings tight to maintain maximum pump effi-ciency.Pump Va

Page 9

OM−06341 PA SERIESOPERATIONPAGE C − 4Safety Shutdown SystemThe unit is equipped with a safety system to auto-matically shut down the engine under cert

Page 10

OM−06341PA SERIESOPERATION PAGE C − 5COLD WEATHER PRESERVATIONIn below freezing conditions, drain the pump toprevent damage from freezing. Also, clean

Page 11

TROUBLE POSSIBLE CAUSE PROBABLE REMEDYPUMP FAILS TOPRIMEStrainer clogged. Check strainer and clean if neces-sary.Suction lift or discharge head too hi

Page 12

Register your newGorman-Rupp pump online atwww.grpumps.comValid serial number and e-mail address required.RECORD YOUR PUMP MODEL AND SERIAL NUMBERPlea

Page 13

TROUBLE POSSIBLE CAUSE PROBABLE REMEDYPUMP STOPS ORFAILS TO DELIVERRATED FLOW ORPRESSURE (cont.)PUMP REQUIRESTOO MUCHPOWERPUMP CLOGSFREQUENTLYImpeller

Page 14 - OPERATION − SECTION C

TROUBLE POSSIBLE CAUSE PROBABLE REMEDYBEARINGS RUNTOO HOTBearing temperature is high, butwithin limits.Align drive properly.Drive misaligned.Check pip

Page 15

OM−06341PA SERIESTROUBLESHOOTINGPAGE D − 4General Condition (Temperature, UnusualNoises or Vibrations, Cracks, Leaks,Loose Hardware, Etc.) IPump Perfo

Page 16

OM−06341PA SERIESMAINTENANCE & REPAIR PAGE E − 1PUMP MAINTENANCE AND REPAIR − SECTION EMAINTENANCE AND REPAIR OF THE WEARING PARTS OF THE PUMP WIL

Page 17

OM−06341 PA SERIESMAINTENANCE & REPAIRPAGE E − 2PARTS PAGEILLUSTRATIONFigure 1. Pump Model PA6C60−4045T−ESP

Page 18 - COLD WEATHER PRESERVATION

ITEM NO.PART NAME PART NUMBERMAT’LCODEQTY ITEM NO.PART NAME PART NUMBERMAT’LCODEQTYOM−06341PA SERIESMAINTENANCE & REPAIR PAGE E − 3Pump Model PA6C

Page 19 - TROUBLESHOOTING − SECTION D

OM−06341 PA SERIESMAINTENANCE & REPAIRPAGE E − 4ILLUSTRATIONFigure 2. Pump Model PA6C60−4045T−ESP

Page 20

ITEM NO.PART NAME PART NUMBERMAT’LCODEQTY ITEM NO.PART NAME PART NUMBERMAT’LCODEQTYOM−06341PA SERIESMAINTENANCE & REPAIR PAGE E − 5Pump Model PA6C

Page 21 - PREVENTIVE MAINTENANCE

OM−06341 PA SERIESMAINTENANCE & REPAIRPAGE E − 6ILLUSTRATIONFigure 3. Pump Model PA6C60−4045T−ESP

Page 22

ITEM NO.PART NAME PART NUMBERMAT’LCODEQTY ITEM NO.PART NAME PART NUMBERMAT’LCODEQTYOM−06341PA SERIESMAINTENANCE & REPAIR PAGE E − 7Pump Model PA6C

Page 23

TABLE OF CONTENTSiINTRODUCTION PAGE I − 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . SAFETY - SE

Page 24 - ILLUSTRATION

OM−06341 PA SERIESMAINTENANCE & REPAIRPAGE E − 8ILLUSTRATIONFigure 4. Pump Model PA6C60−4045T−ESP

Page 25 - (From S/N 1479001 Up)

ITEM NO.PART NAME PART NUMBERMAT’LCODEQTY ITEM NO.PART NAME PART NUMBERMAT’LCODEQTYOM−06341PA SERIESMAINTENANCE & REPAIR PAGE E − 9Pump Model PA6C

Page 26

OM−06341 PA SERIESMAINTENANCE & REPAIRPAGE E − 10ILLUSTRATIONFigure 5. PA6C60−(SAE 3/10) Pump Assembly

Page 27 - PARTS LIST (Cont’d)

OM−06341PA SERIESMAINTENANCE & REPAIR PAGE E − 11PA6C60−(SAE 3/10) Pump AssemblyPARTS LISTITEM NO.PART NAMEPART NUMBERMAT’LCODEQTY1 66F60−(SAE 3/1

Page 28

OM−06341 PA SERIESMAINTENANCE & REPAIRPAGE E − 12ILLUSTRATIONFigure 6. 66F60−(SAE 3/10) Pump Subassembly

Page 29

ITEM NO.PART NAME PART NUMBERMAT’LCODEQTY ITEM NO.PART NAME PART NUMBERMAT’LCODEQTYOM−06341PA SERIESMAINTENANCE & REPAIR PAGE E − 13 PARTS LIST66F

Page 30

OM−06341 PA SERIESMAINTENANCE & REPAIRPAGE E − 14ILLUSTRATIONFigure 7. 44163−430 Repair Rotating Assembly

Page 31

ITEM NO.PART NAME PART NUMBERMAT’LCODEQTY ITEM NO.PART NAME PART NUMBERMAT’LCODEQTYOM−06341PA SERIESMAINTENANCE & REPAIR PAGE E − 15PARTS LIST4416

Page 32

OM−06341 PA SERIESMAINTENANCE & REPAIRPAGE E − 16ILLUSTRATIONFigure 8. 48275−005 Priming Chamber KitPARTS LISTITEM NO.PART NAMEPART NUMBERMAT’LCO

Page 33

OM−06341PA SERIESMAINTENANCE & REPAIR PAGE E − 17ILLUSTRATIONFigure 9. 46112−709 Priming Chamber AssemblyPARTS LISTITEM NO.PART NAMEPART NUMBERMA

Page 34

TABLE OF CONTENTS(continued)iiPARTS LIST:Pump Model PAGE E − 3. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Page 35 - PARTS LIST

OM−06341 PA SERIESMAINTENANCE & REPAIRPAGE E − 18ILLUSTRATIONFigure 10. 44162−159 Drive AssemblyPARTS LISTITEM NO.PART NAMEPART NUMBERMAT’LCODEQT

Page 36

OM−06341PA SERIESMAINTENANCE & REPAIR PAGE E − 19PUMP AND SEAL DISASSEMBLYAND REASSEMBLYReview all SAFETY information in Section A.Follow the inst

Page 37

PA SERIESOM−06341MAINTENANCE & REPAIRPAGE E − 20direct exposure or emitted fumes. Wearadequate protective clothing whenworking on the pump or pipi

Page 38

OM−06341PA SERIESMAINTENANCE & REPAIR PAGE E − 21gine. Disconnect the discharge piping from thepump casing.Remove the hardware (8 and 9) securing

Page 39

PA SERIESOM−06341MAINTENANCE & REPAIRPAGE E − 22death could result. Suction and dis-charge hoses and piping must be re-moved from the pump before

Page 40

OM−06341PA SERIESMAINTENANCE & REPAIR PAGE E − 23be replaced any time the shaft and bear-ings are removed.Clean the bearing housing, shaft and all

Page 41

PA SERIESOM−06341MAINTENANCE & REPAIRPAGE E − 24movement has occurred, use a suitably sizedsleeve and a press to reposition the bearingsagainst th

Page 42

OM−06341PA SERIESMAINTENANCE & REPAIR PAGE E − 25If the complete coupling assembly is being re-placed, apply ‘Loctite Retaining Compound No.242’ o

Page 43

PA SERIESOM−06341MAINTENANCE & REPAIRPAGE E − 26SEAL PLATEO-RINGSIMPELLERSHAFTSTATIONARYSEATROTATINGELEMENTDRIVE BANDBELLOWSIMPELLERSHIMSIMPELLERS

Page 44

OM−06341PA SERIESMAINTENANCE & REPAIR PAGE E − 27The shaft and impeller threads must becompletely clean before reinstalling the im-peller. Even th

Page 45

OM−06341PA SERIESPAGE I − 1INTRODUCTIONINTRODUCTIONThank You for purchasing a Gorman-Rupp pump.Read this manual carefully to learn how to safelyinstal

Page 46

PA SERIESOM−06341MAINTENANCE & REPAIRPAGE E − 28adjusting screws so the holes in the collars for thelocking screws align approximately with the ho

Page 47

OM−06341PA SERIESMAINTENANCE & REPAIR PAGE E − 29LUBRICATION(Figure 6)Seal AssemblyFill the seal cavity through the hole for the ventedplug (14) w

Page 48 - F (71C). Do not

For U.S. and International Warranty Information,Please Visit www.grpumps.com/warrantyor call:U.S.: 419−755−1280International: +1−419−755−1352For Canad

Page 49

PA SERIESOM−06341PAGE A − 1SAFETYSAFETY - SECTION AThis information applies to Prime AireSeries pumps. Refer to the manual ac-companying the engine o

Page 50

PA SERIESOM−06341PAGE A − 2 SAFETYheated pump. Vapor pressure within thepump can cause parts being disen-gaged to be ejected with great force. Al-low

Page 51 - and maintain it at

PA SERIES OM−06341PAGE B − 1INSTALLATIONINSTALLATION − SECTION BReview all SAFETY information in Section A.Since pump installations are seldom identic

Page 52 -  ST. THOMAS, ONTARIO, CANADA

OM−06341 PA SERIESPAGE B − 2 INSTALLATIONc. Carefully read all tags, decals, and markingson the pump assembly, and perform all dutiesindicated. Note t