OM-06123−02
May 9, 2008
Rev. A 02-17-09
ACE
THE GORMAN-RUPP COMPANY D MANSFIELD, OHIO
www.grpumps.com
GORMAN-RUPP OF CANADA LIMITED D ST. THOMAS, ONTARIO, CANADA Printed in U.S.A.
e2008 The Gorman-Rupp Company
INSTALLATION, OPERATION,
AND MAINTENANCE MANUAL
WITH PARTS LIST
VGH SERIES PUMP
MODEL
VGH3B31−B
Vue de la page 0
1 2 3 4 5 6 ... 32 33

Résumé du contenu

Page 1 - VGH3B31−B

OM-06123−02May 9, 2008Rev. A 02-17-09ACETHE GORMAN-RUPP COMPANY D MANSFIELD, OHIOwww.grpumps.comGORMAN-RUPP OF CANADA LIMITED D ST. THOMAS, ONTARIO,

Page 2

VGH SERIES OM−06123PAGE B − 3INSTALLATIONSuction Lines In SumpsIf a single suction line is installed in a sump, itshould be positioned away from the w

Page 3 - TABLE OF CONTENTS

OM−06123 VGH SERIESPAGE B − 4 INSTALLATIONDISCHARGE LINESSiphoningDo not terminate the discharge line at a level lowerthan that of the liquid being pu

Page 4 - (continued)

VGH SERIES OM−06123PAGE B − 5INSTALLATIONWhen checking alignment, disconnectthe power source to ensure that thepump will remain inoperative.Adjusting

Page 5 - INTRODUCTION

OM−06123 VGH SERIESPAGE B − 6 INSTALLATIONMISALIGNED:SHAFTSNOT PARALLELMISALIGNED:SHAFTSNOT IN LINEALIGNED: SHAFTSPARALLEL ANDSHEAVES IN LINEFigure 3C

Page 6 - SAFETY - SECTION A

VGH SERIESOM−06123OPERATION PAGE C − 1OPERATION − SECTION CReview all SAFETY information in Section A.Follow the instructions on all tags, labels and

Page 7 - PAGE A − 2 SAFETY

VGH SERIESOM−06123OPERATIONPAGE C − 2suction line and pump casing. To prime a pumpwith a hand vacuum pump, open the cock on thepump priming line. Oper

Page 8 - INSTALLATION − SECTION B

VGH SERIESOM−06123OPERATION PAGE C − 3OPERATIONPump speed and operating points must bewithin the continuous performance rangeshown on the pump curve (

Page 9 - SUCTION LINES

VGH SERIESOM−06123OPERATIONPAGE C − 4To avoid serious damage to the pump,check for unusual noises or excessive vi-bration while the pump is running. I

Page 10 - Figure 1 shows

VGH SERIESOM−06123OPERATION PAGE C − 5uid from an external source. When handling cleanliquids, flushing liquid is taken from the pump dis-charge and s

Page 11

OM−06123VGH SERIESTROUBLESHOOTING PAGE D − 1TROUBLESHOOTING − SECTION BReview all SAFETY information in Section A.Before attempting to open or service

Page 12

Register your newGorman-Rupp pump online atwww.grpumps.comValid serial number and e-mail address required.RECORD YOUR PUMP MODEL AND SERIAL NUMBERPlea

Page 13

OM−06123 VGH SERIESTROUBLESHOOTINGPAGE D − 2Table D-1 Troubleshooting Chart (Continued) TROUBLE POSSIBLE CAUSE PROBABLE REMEDYPUMP STOPS OR FAILSTO D

Page 14 - OPERATION − SECTION C

OM−06123VGH SERIESTROUBLESHOOTING PAGE D − 3Table D-1 Troubleshooting Chart (Continued) TROUBLE POSSIBLE CAUSE PROBABLE REMEDYBEARINGS RUN TOOHOTBear

Page 15

OM−06123 VGH SERIESTROUBLESHOOTINGPAGE D − 4General Condition (Temperature, UnusualNoises or Vibrations, Cracks, Leaks,Loose Hardware, Etc.) IPump Per

Page 16

VGH SERIES OM−06123MAINTENANCE & REPAIR PAGE E − 1PUMP MAINTENANCE AND REPAIR - SECTION EMAINTENANCE AND REPAIR OF THE WEARING PARTS OF THE PUMP W

Page 17

VGH SERIESOM−06123MAINTENANCE & REPAIRPAGE E − 2SECTION DRAWINGPARTS PAGEFigure 1. Pump Assembly VGH3B31−B

Page 18

ITEM NO.PART NAME PART NUMBERMAT’LCODEQTY ITEM NO.PART NAME PART NUMBERMAT’LCODEQTYVGH SERIES OM−06123MAINTENANCE & REPAIR PAGE E − 3PARTS LISTPum

Page 19 - TROUBLESHOOTING − SECTION B

VGH SERIESOM−06123MAINTENANCE & REPAIRPAGE E − 4PUMP AND SEAL DISASSEMBLYAND REASSEMBLYReview all Safety information in Section A.Follow the instr

Page 20

OM−06123VGH SERIESMAINTENANCE & REPAIR PAGE E − 5move the seal plate gasket (41) and clean the mat-ing surfaces.Immobilize the impeller shaft (22)

Page 21 - PREVENTIVE MAINTENANCE

VGH SERIESOM−06123MAINTENANCE & REPAIRPAGE E − 6Clean the bearing housing, shaft and all compo-nent parts (except the bearings) with a soft cloths

Page 22

OM−06123VGH SERIESMAINTENANCE & REPAIR PAGE E − 7Press the oil seal (23) into the bearing cover (25)with the lip positioned as shown in Figure 1.

Page 23

TABLE OF CONTENTSiINTRODUCTION PAGE I − 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . SAFETY - SE

Page 24 - SECTION DRAWING

VGH SERIESOM−06123MAINTENANCE & REPAIRPAGE E − 8Do not attempt to separate the seal, this coulddamage the seal. Individual parts are not sold sep-

Page 25 - (From S/N 1379872 Up)

OM−06123VGH SERIESMAINTENANCE & REPAIR PAGE E − 9sleeve is just flush with the shaft shoulder. Securethe sleeve to the shaft with the setscrew (54

Page 26

VGH SERIESOM−06123MAINTENANCE & REPAIRPAGE E − 10Do not fill the bearing cavity through the vent plugin the top of the housing. This will result i

Page 27

For U.S. and International Warranty Information,Please Visit www.grpumps.com/warrantyor call:U.S.: 419−755−1280International: +1−419−755−1352For Canad

Page 28 - until the bearing (19)

TABLE OF CONTENTS(continued)iiBEARING TEMPERATURE CHECK PAGE C − 4. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Page 29

VGH SERIESOM−06123PAGE I − 1INTRODUCTIONINTRODUCTIONThank You for purchasing a Gorman-Rupp pump.Read this manual carefully to learn how to safelyinsta

Page 30 - _F (71_C). Do not

VGH SERIESOM−06123PAGE A − 1SAFETYSAFETY - SECTION AThis information applies to VGH Seriesbasic pumps. Gorman-Rupp has nocontrol over or particular kn

Page 31 - LUBRICATION

VGH SERIESOM−06123PAGE A − 2 SAFETYIf this pump is used with volatile and/orflammable liquids, overheating mayproduce dangerous fumes. Take pre-cautio

Page 32

VGH SERIES OM−06123PAGE B − 1INSTALLATIONINSTALLATION − SECTION BReview all SAFETY information in Section A.Since pump installations are seldom identi

Page 33 - D ST. THOMAS, ONTARIO, CANADA

OM−06123 VGH SERIESPAGE B − 2 INSTALLATIONMountingLocate the pump in an accessible place as close aspractical to the liquid being pumped. Level mount-