Vue de la page 0
OM−00793−03
February 25, 1981
Rev. B 01-21-10
ACDEGW
THE GORMAN-RUPP COMPANY MANSFIELD, OHIO
www.grpumps.com
GORMAN-RUPP OF CANADA LIMITED ST. THOMAS, ONTARIO, CANADA Printed in U.S.A.
1981 The Gorman-Rupp Company
INSTALLATION, OPERATION,
AND MAINTENANCE MANUAL
WITH PARTS LIST
80 SERIES PUMP
MODEL
81 1/4B3−E.33 1P
Vue de la page 0
1 2 3 4 5 6 ... 25 26

Résumé du contenu

Page 1 - 81 1/4B3−E.33 1P

OM−00793−03February 25, 1981Rev. B 01-21-10ACDEGWTHE GORMAN-RUPP COMPANY  MANSFIELD, OHIOwww.grpumps.comGORMAN-RUPP OF CANADA LIMITED  ST. THOMAS,

Page 2

80 SERIES OM−00793PAGE B − 3INSTALLATIONmum use of elbows and fittings, which substan-tially increase friction loss. If elbows are necessary,use the l

Page 3

OM−00793 80 SERIESPAGE B − 4 INSTALLATIONtance equal to at least 3 times the diameter of thesuction pipe.Suction Line PositioningThe depth of submerge

Page 4 - (continued)

80 SERIES OM−00793PAGE B − 5INSTALLATIONBypass LinesIf a system check valve is used due to high dis-charge head, it may be necessary to vent trappedai

Page 5 - INTRODUCTION

OM−0079380 SERIESOPERATION PAGE C − 1OPERATION − SECTION CReview all SAFETY information in Section A.Follow the instructions on all tags, labels andde

Page 6 - SAFETY - SECTION A

OM−00793 80 SERIESOPERATIONPAGE C − 2Lines Without a BypassOpen all valves in the discharge line and start themotor. Priming is indicated by a positiv

Page 7 - PAGE A − 2 SAFETY

OM−0079380 SERIESOPERATION PAGE C − 3After stopping the pump, disconnect the incomingpower to the motor and lock it out to ensure that thepump will re

Page 8 - INSTALLATION − SECTION B

TROUBLE POSSIBLE CAUSE PROBABLE REMEDYPUMP FAILS TOPRIMEStrainer clogged. Check strainer and clean if neces-sary.Suction lift or discharge head too hi

Page 9

TROUBLE POSSIBLE CAUSE PROBABLE REMEDYPUMP STOPS ORFAILS TO DELIVERRATED FLOW ORPRESSURE (cont.)PUMP REQUIRESTOO MUCHPOWERPUMP CLOGSFREQUENTLYFree imp

Page 10 - SUCTION LINES

OM−0079380 SERIESTROUBLESHOOTING PAGE D − 3PREVENTIVE MAINTENANCESince pump applications are seldom identical, andpump wear is directly affected by su

Page 11

80 SERIES OM−00793MAINTENANCE & REPAIR PAGE E − 1PUMP MAINTENANCE AND REPAIR - SECTION EMAINTENANCE AND REPAIR OF THE WEARING PARTS OF THE PUMP WI

Page 12

Register your newGorman-Rupp pump online atwww.grpumps.comValid serial number and e-mail address required.RECORD YOUR PUMP MODEL AND SERIAL NUMBERPlea

Page 13 - OPERATION − SECTION C

80 SERIESOM−00793MAINTENANCE & REPAIRPAGE E − 2SECTION DRAWINGPARTS PAGEMOTOR END VIEWFigure 1. Pump Model 81 1/4B3−E.33 1P

Page 14

80 SERIES OM−00793MAINTENANCE & REPAIR PAGE E − 3PARTS LISTPump Model 81 1/4B3−E.33 1P(From S/N 24971 Up)If your pump serial number is followed by

Page 15

80 SERIESOM−00793MAINTENANCE & REPAIRPAGE E − 4PUMP AND SEAL DISASSEMBLYAND REASSEMBLYReview all SAFETY information in Section A.Follow the instru

Page 16 - TROUBLESHOOTING − SECTION D

OM−0079380 SERIESMAINTENANCE & REPAIR PAGE E − 5Seal Removal(Figures 1 and 2)Remove the seal spring.Apply oil to the seal area of the shaft and wo

Page 17

80 SERIESOM−00793MAINTENANCE & REPAIRPAGE E − 6PUMP CASINGMOTORSHAFTSTATIONARYSEATSTATIONARYELEMENTROTATINGELEMENTDRIVE BANDIMPELLERSHIMSIMPELLERS

Page 18 - PREVENTIVE MAINTENANCE

OM−0079380 SERIESMAINTENANCE & REPAIR PAGE E − 7Suction Flap Valve Reassembly andInstallationIf the suction flap valve was disassembled, securethe

Page 19 - T-11-18-76-REV

For U.S. and International Warranty Information,Please Visit www.grpumps.com/warrantyor call:U.S.: 419−755−1280International: +1−419−755−1352For Canad

Page 20 - SECTION DRAWING

TABLE OF CONTENTSiINTRODUCTION PAGE I − 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . SAFETY - SE

Page 21 - (From S/N 24971 Up)

TABLE OF CONTENTS(continued)iiPARTS LIST:Pump Model PAGE E − 3. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Page 22

80 SERIESOM−00793PAGE I − 1INTRODUCTIONINTRODUCTIONThank You for purchasing a Gorman-Rupp pump.Read this manual carefully to learn how to safelyinstal

Page 23

80 SERIESOM−00793PAGE A − 1SAFETYSAFETY - SECTION AThis information applies to 80 Serieselectric motor driven pumps. Refer tothe manual accompanying t

Page 24

80 SERIESOM−00793PAGE A − 2 SAFETYthe applicable local code, the Nationalor local code shall take precedence.The electrical power used to operatethis

Page 25 - LUBRICATION

80 SERIES OM−00793PAGE B − 1INSTALLATIONINSTALLATION − SECTION BReview all SAFETY information in Section A.Since pump installations are seldom identic

Page 26 -  ST. THOMAS, ONTARIO, CANADA

OM−00793 80 SERIESPAGE B − 2 INSTALLATIONing, check for loose hardware at mating sur-faces.c. Carefully read all tags, decals, and markingson the pump